INSULATED UPPER BOOM
The 8 in. x 10 in. (200 mm x 250 mm) rectangular upper boom is
constructed of high strength filament-wound epoxy resin
fiberglass. The fiberglass has a gel coat and a high gloss durable
urethane finish for added weather protection and water beading.
The fiberglass boom is certified for 46 KV and below in accordance
with ANSI A92.2 Category C dielectric rating requirements. The
upper boom articulates a total of 2400 relative to the lower boom
from -100 to +2300. A side by side boom design allows low travel
height and improved platform access. The upper boom articulation
is accomplished by a double acting hydraulic cylinder and 4-bar
mechanical linkage. The system does not use any cables and
the booms can be stowed in any sequence. A double acting
holding valve is provided. An upper boom storage cradle mounted
on the turret assures solid boom support in the stowed position.
A ratchet-type boom tie-down strap is included.
LOWER BOOM
The lower boom is designed and constructed from high strength,
12 in. (300 mm) square, steel tube. Boom articulation is 1150
from horizontal to 250 past vertical. Articulation is achieved by using
a double-acting hydraulic cylinder equipped with two integral
holding valves.
ELECTRICAL INSULATION SPECIFICATIONS
The upper boom is tested and certified as standard for electrical
work at 46kV and below in ccordance with ANSI A92.2 Category
C dielectric rating requirements. The chassis insulating system
(lower boom insert) is also tested and certified according to ANSI
A92.2.
CYLINDERS
Both the upper boom and lower boom cylinders are the threaded
end-cap design. Both boom cylinders are equipped with two
integral holding valves to prevent creep of the booms and to lock
the booms in position in the event of a hydraulic failure.
CONTINUOUS ROTATION
Rotation is continuous and unrestricted in either direction. The
rotation system consists of a hydraulically driven worm and spur
gear acting on a shear-ball rotation bearing. The critical bolts
holding the lift to the rotation bearing and the rotation bearing to
the pedestal are grade 8. These critical bolts are torque seal
marked to provide a quick means of detecting any loosening. An
eccentric ring gearbox mounting allows for precise backlash
adjustments sequence.
MECHANICAL PLATFORM LEVELING
Platform leveling is achieved automatically through a completely
enclosed parallelogram system. The major components of this
system include 1 in. (25 mm) diameter fiberglass leveling rods and
No. 100 high strength roller chain. There are no cables used in
this system. The fiberglass leveling rods maintain the insulation
gaps in all boom positions and are 100% tested at twice the rated
load. The tension is adjusted by means of a threaded rod in the
upper and lower boom and platform leveling is adjusted by
another threaded rod at the turret.
LUBRICATION
Non-lube bearings are used at most pivot points. Only the rotation
bearing and leveling chains require periodic lubrication.
GENERAL SPECIFICATIONS (Based on 40 in. (1.02 m) Frame Height)
| |
VO-43-I |
| Horizontal Reach, Overcenter |
34 ft (10.4m) |
| Horizontal Reach, Non-Overcenter |
33 ft 1 in (10.1m) |
| Maximum Platform Capacity |
400 lbs (183kg) |
| Lower Boom Lift Eye Capacity |
1500 lbs (680kg) |
| |
|
| With Standard Pedestal |
| Height to Bottom of Platform |
42 ft 10 in (13m) |
| Working Height |
47 ft 10 in (14.60m) |
| Stowed Travel Height |
10 ft 3 in (3.1m) |
| |
|
| Hydraulic System |
|
| Operating Pressure |
2500 PSI (176 kg/cm2) |
| Flow Rate |
6 GPM (23 lpm) |
| Filtration |
10 micron return
100 mesh section |
| System Type |
Open center |
| Power Source |
PTO Pump |

*NOTE:
- Specifications may vary without prior notification
- Required GVWR can vary significantly with chassis, lift mountings location, service body, accessories, and desired payload.
OPTIONS:
- 400lbs. Platform Capacity
- Platform Liner and Cover
- Manual Platform Tilt
- 900 Platform Rotation
- Two-Speed Manual Throttle-Control
- Emergency Power
- Category B Dielectric Testing & Certification
- Outriggers or Torsion Bars
- Tool Port Pressure & Flow Control
- Second Set of Tool Power Outlets
|

Articulation allows for easy
access to compartments. |

Torsion bars provide additional
chassis support. |

Platform tilt allows for easy cleaning.
|
|